This Technical Note documents how the Model 1895 box magazine manages rimmed cartridges throughout the feeding cycle.
Unlike tubular magazines, the 1895 magazine actively controls cartridge position, angle, and release timing—making geometry critical to reliability.
I. Why Rim Control Matters in the Model 1895
Rimmed cartridges introduce the risk of rim-over-rim interference.
In the Model 1895:
- Cartridges stack vertically
- Rims must remain staggered correctly
- Release timing must prevent overlap
Any disruption can cause partial feeds or stoppages.
II. Magazine Body Geometry
The magazine body establishes the baseline alignment of cartridges.
Critical features include:
- Internal width and taper
- Front-to-rear cartridge angle
- Vertical presentation height
Even minor deformation alters cartridge attitude during feeding.
III. Feed Lip Design & Release Timing
Feed lips control when and how the cartridge is released to the bolt.
Proper feed lip geometry ensures:
- Controlled forward movement
- Correct rim clearance
- Consistent release point
Bent or worn feed lips are a primary cause of feeding failures.
IV. Follower Angle & Cartridge Bias
The follower determines cartridge nose angle and rim stacking behavior.
Its design:
- Biases the cartridge upward
- Maintains rim separation
- Stabilizes the stack under recoil
Follower tilt or wear disrupts these functions.
(See TN-04 — Follower Design & Spring Dynamics)
V. Spring Tension & Stack Control
Spring tension maintains upward pressure on the cartridge stack.
Inadequate tension results in:
- Delayed cartridge presentation
- Inconsistent release timing
- Increased susceptibility to recoil-induced movement
Excessive tension can also disrupt smooth feeding.
VI. Bolt Strip & Feed Sequence
During feeding:
- The bolt strips the top cartridge forward
- The rim clears the feed lips
- The cartridge enters the chamber along a guided path
Timing errors at any stage cause nose-dives or bolt-over-base malfunctions.
VII. Common Failure Modes
Most feeding issues trace back to magazine geometry.
Common failure modes include:
- Rim lock due to improper stacking
- Partial release from bent feed lips
- Follower-induced nose dives
Symptoms often appear intermittently before becoming persistent.
VIII. Diagnostic Checklist
Effective diagnosis should proceed in order:
- Inspect feed lips for symmetry and wear
- Check follower tilt and freedom of movement
- Evaluate spring tension and condition
Replacing ammunition without inspection rarely resolves magazine-based issues.
Technical Scope — TN-03 (Box Magazine Geometry & Rimmed Cartridge Control)
Primary Focus: Magazine body geometry, feed lip design and release timing, follower angle and bias, spring tension effects, rimmed cartridge control, feeding sequence mechanics, and diagnostic indicators for the Model 1895 box magazine system.
Referenced By:

WARNING: